Specifications
| Characteristic | Published value |
|---|---|
| Standard | IEC/EN 60947-4-1 Source ↗ |
| Certifications | CE, UL, CCC, RoHS Source ↗ |
| Utilization Category | AC-1, AC-3 Source ↗ |
| Rated Operational Voltage (Ue) | Up to 690 V Source ↗ |
| Rated Insulation Voltage (Ui) | 690 V Source ↗ |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV Source ↗ |
| AC-3 (400 V) | 9 A, 12 A, 18 A, 25 A Source ↗ |
| 220/230 V | 2.2–5.5 kW Source ↗ |
| 380/400 V | 4–11 kW Source ↗ |
| 660/690 V | 5.5–15 kW Source ↗ |
| Rated Frequency | 50/60 Hz Source ↗ |
| AC | 24, 48, 110, 127, 220, 230, 380, 400 V Source ↗ |
| DC | 12, 24, 48, 110, 220 V Source ↗ |
| Inrush | 50–70 VA (AC) / 3.5–5 W (DC) Source ↗ |
| Holding | 4–10 VA (AC) / 2.5 W (DC) Source ↗ |
| Mechanical Life | 10 million operations Source ↗ |
| Electrical Life (AC-3) | 1 million operations Source ↗ |
| AC-3 | 600 Source ↗ |
| Mechanical | 3,600 Source ↗ |
| Ambient Temperature | −5 °C to +40 °C Source ↗ |
| Altitude | ≤ 2,000 m Source ↗ |
| Mounting Position | Vertical ±30° inclination Source ↗ |
| Protection Degree | IP20 Source ↗ |
| Connection Type | Screw or fast terminal (for NC7K versions) Source ↗ |
| Terminal Capacity | 1.5–6 mm² Source ↗ |
| Tightening Torque | 0.8–1.2 N·m Source ↗ |
| Standard | 1NO + 1NC Source ↗ |
| Optional | 2NO + 2NC Source ↗ |
| AC-15 | 380 V / 0.95 A Source ↗ |
| DC-13 | 220 V / 0.15 A Source ↗ |
| Mounting Type | DIN rail (TH35-7.5) or panel mounting Source ↗ |
| Auxiliary blocks | F4 or F5 series Source ↗ |
| Time-delay blocks | F5-T0/F5-T2 (0.1–180 s) Source ↗ |
| Thermal overload relays | NR2 series (up to 25 A) Source ↗ |
| Mechanical interlocks | NJL7 series Source ↗ |
| Applications | Motor starters, lighting circuits, HVAC systems, and control panels Source ↗ |
Published ranges and options describe this model or family; confirm the selected configuration for your application.
Datasheets & technical documents
- NC7-AC Contactor-Catalog.pdf ↗Catalog
- 2004-NC7-09~95-AC Contactor-Manual.pdf ↗Manual
- 2004-NC7-115~620-AC Contactor-Manual.pdf ↗Manual
- 2310-NC7-115-AC Contactor-CB Certificate.pdf ↗Certificate
- 2211-NC7-AC Contactor-CE Declaration Certificate.pdf ↗Certificate
- 2109-NC7-250-AC Contactor-CB Certificate.pdf ↗Certificate
- 2109-NC7-620-AC Contactor-CB Certificate.pdf ↗Certificate
- 2109-NC7-300-AC Contactor-CB Certificate.pdf ↗Certificate
- 2109-NC7-95-AC Contactor-CB Certificate.pdf ↗Certificate
- 2109-NC7-205-AC Contactor-CB Certificate.pdf ↗Certificate
- 2109-NC7-65-AC Contactor-CB Certificate.pdf ↗Certificate
- 2109-NC7-38-AC Contactor-CB Certificate.pdf ↗Certificate
- 2109-NC7-410-AC Contactor-CB Certificate.pdf ↗Certificate
- 2109-NC7-25-AC Contactor-CB Certificate.pdf ↗Certificate
- 2109-NC7-475-AC Contactor-CB Certificate.pdf ↗Certificate
- 2109-NC7-22-AC Contactor-CB Certificate.pdf ↗Certificate
- 1510-NC7-475-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1510-NC7-250-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1510-NC7-620-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1510-NC7-300-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1510-NC7-205-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1510-NC7-410-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1509-NC7-115-170-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1311-NC7-40-65-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1311-NC7-80-95-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1311-NC7-09-12-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1311-NC7-18-22-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1311-NC7-32-38-AC Contactor-KEMA Certificate.pdf ↗Certificate
- 1311-NC7-25-AC Contactor-KEMA Certificate.pdf ↗Certificate
- NC7-32~38-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-18-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-410-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-09~12-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-4011~6511-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-250-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-475-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-620-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-1811~2211-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-8011~9511-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-300-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-205-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-115~170-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-0911~1211-AC Contactor-Drawing-2D.pdf ↗Drawing
- NC7-25-AC Contactor-Drawing-2D.pdf ↗Drawing
Project suitability: Global catalog range. Canadian project suitability, certification and availability must be confirmed for the selected model.
Discuss your requirements
- Application and installation environment
- Electrical ratings and required configuration
- Quantity, project location and delivery requirements
PRODUCT KNOWLEDGE FOR YOUR TEAM
Want to learn about this product?
Discuss NC7 AC Contactor with Innovelec. Bring your application questions, compare options, or arrange a session for your team.
LET US HELP YOU FIND IT
Can’t find what you need?
Tell us the model, application or specifications. Our team can help identify the right product and request missing technical information.
YOUR PROJECT SHORTLIST
Quote list 0
Add products to prepare one inquiry for our team.
Your inquiry is sent only when you send the email. Include your project location, specifications and required date. You can attach drawings in your email app.