Circuit protection & motor control · Model / series
NJBK1
CHINT NJBK1 for circuit protection & motor control applications. Published details include Standard Compliance: IEC/EN 60947-4-1; Rated Insulation Voltage: 690 V. Ask Innovelec about selection, project requirements and availability.
Specifications
| Characteristic | Published value |
|---|---|
| Standard Compliance | IEC/EN 60947-4-1 Source ↗ |
| Rated Insulation Voltage | 690 V Source ↗ |
| Rated Operating Current | 1 A – 400 A Source ↗ |
| Rated Control Voltage | AC 220 V / AC 380 V (50 Hz) Source ↗ |
| Rated Impulse Withstand Voltage | 4 kV Source ↗ |
| Conditional Short-Circuit Current | 3 kA Source ↗ |
| Ambient Temperature | −5 °C to +40 °C (average ≤ +35 °C in 24 h) Source ↗ |
| Storage Temperature | −25 °C to +55 °C Source ↗ |
| Altitude | ≤ 2000 m Source ↗ |
| Relative Humidity | ≤ 50% at +40 °C (higher humidity allowed at lower temperatures) Source ↗ |
| Installation Category | Class III Source ↗ |
| Pollution Degree | Class 3 Source ↗ |
| Protection Degree | IP20 Source ↗ |
| Display | LED display showing real-time current, setting status, fault codes, and max phase current Source ↗ |
| Setting Method | Adjustable knob for current and trip class Source ↗ |
| Published specification | Overload protection (inverse-time characteristics) Source ↗ |
| Published specification | Phase loss protection Source ↗ |
| Published specification | Three-phase current imbalance protection Source ↗ |
| Overload Curve Options | 5 selectable inverse-time characteristics (Class 5, 10A, 10, 20, 30) Source ↗ |
| Tripping Delay | Configurable per curve type Source ↗ |
| Fault Memory | Retains latest fault code and phase current reading Source ↗ |
| Published specification | Test/Reset button for manual trip simulation and reset Source ↗ |
| Published specification | Pluggable terminal block for convenient wiring Source ↗ |
| Two NO contacts | (95–98 for protection, 07–08 for alarm) Source ↗ |
| Published specification | 415 V / 0.95 A Source ↗ |
| Published specification | 240 V / 1.5 A Source ↗ |
| Thermal Current (Ith) | 5 A Source ↗ |
| Installation Type | DIN-rail or panel-mounted (screw fixing) Source ↗ |
| Enclosure Type | Integrated design, compact structure Source ↗ |
| Operation Duty | 8-hour or continuous Source ↗ |
| Electromagnetic Environment | Class B industrial Source ↗ |
| Published specification | NJBK1-80/5 (1–5 A, 0.5–2.5 kW) Source ↗ |
| Published specification | NJBK1-80/10 (2–10 A, 1–5 kW) Source ↗ |
| Published specification | NJBK1-80/30 (6–30 A, 3–15 kW) Source ↗ |
| Published specification | NJBK1-80/80 (16–80 A, 8–40 kW) Source ↗ |
| Published specification | NJBK1-400/200 (40–200 A, 20–100 kW) Source ↗ |
| Published specification | NJBK1-400/400 (80–400 A, 40–200 kW) Source ↗ |
| Published specification | 113 × 73 × 110 mm (NJBK1-80) Source ↗ |
| Published specification | 142.5 × 72.5 × 121 mm (NJBK1-400) Source ↗ |
Published ranges and options describe this model or family; confirm the selected configuration for your application.
Datasheets & technical documents
Project suitability: Global catalog range. Canadian project suitability, certification and availability must be confirmed for the selected model.
Discuss your requirements
- Application and installation environment
- Electrical ratings and required configuration
- Quantity, project location and delivery requirements
PRODUCT KNOWLEDGE FOR YOUR TEAM
Want to learn about this product?
Discuss NJBK1 with Innovelec. Bring your application questions, compare options, or arrange a session for your team.
LET US HELP YOU FIND IT
Can’t find what you need?
Tell us the model, application or specifications. Our team can help identify the right product and request missing technical information.
YOUR PROJECT SHORTLIST
Quote list 0
Add products to prepare one inquiry for our team.
Your inquiry is sent only when you send the email. Include your project location, specifications and required date. You can attach drawings in your email app.