Circuit protection & motor control · Model / series
NVF3M
CHINT NVF3M for circuit protection & motor control applications. Published details include Standard Compliance: GB/T 12668.2-2002 / IEC 61800-2; Input Voltage Range: 220 V / 380 V ±15 %. Ask Innovelec about selection, project requirements and availability.
Specifications
| Characteristic | Published value |
|---|---|
| Standard Compliance | GB/T 12668.2-2002 / IEC 61800-2 Source ↗ |
| Input Voltage Range | 220 V / 380 V ±15 % Source ↗ |
| Input Frequency | 47 – 63 Hz Source ↗ |
| Output Frequency | 0 – 300 Hz Source ↗ |
| Control Modes | V/F Control | Sensorless Vector Control Source ↗ |
| Starting Torque | 150 % at 0.5 Hz (without PG control) Source ↗ |
| Speed Control Precision | ± 0.5 % of max speed Source ↗ |
| Speed Ratio | 1 : 100 (vector) | 1 : 50 (V/F) Source ↗ |
| Overload Capacity | 150 % rated current for 60 s Source ↗ |
| Torque Boost | Automatic / manual (0.1 % – 30 %) Source ↗ |
| Carrier Frequency | 0.5 – 15 kHz adjustable Source ↗ |
| Published specification | 3-phase version – standard Source ↗ |
| Published specification | 1-phase version – optional Source ↗ |
| Dynamic & DC Braking | Configurable; 0 – 60 Hz operation Source ↗ |
| PID Controller | Built-in closed-loop process control Source ↗ |
| AVR Function | Automatic voltage regulation to stabilize output Source ↗ |
| Automatic Current Limiting | Prevents overload trips Source ↗ |
| Jog Function | 0 – 50 Hz with 0.1–6000 s acc/dec time Source ↗ |
| Published specification | Over-current, over-voltage, under-voltage, overheating, open phase, overload, PID disconnection and more Source ↗ |
| Cooling Method | High-speed DC fan cooling Source ↗ |
| Protection Degree | IP20 Source ↗ |
| Digital Inputs | 5 (incl. 1 high-speed pulse input) Source ↗ |
| Analog Inputs | AI1, AI2 (0 – 10 V / 4 – 20 mA) Source ↗ |
| Relay Output | 1 (NO/NC 5 A/3 A) Source ↗ |
| Analog Output | 0 – 10 V / 4 – 20 mA Source ↗ |
| Communication Interface | RS-485 (MODBUS RTU) Source ↗ |
| Operating Temperature | −10 °C to +40 °C (derate 1 % per °C > 40 °C) Source ↗ |
| Altitude | ≤ 1000 m (rated) – derate 10 % per 1000 m above Source ↗ |
| Humidity | 5 – 95 % RH (non-condensing) Source ↗ |
| Applicable Motor Power | 0.4 – 1.5 kW (single / three-phase) Source ↗ |
| Installation Type | Wall / panel mount Source ↗ |
| Published specification | Medical and laboratory equipment Source ↗ |
| Published specification | Food & beverage processing Source ↗ |
| Published specification | Textile and woodworking machinery Source ↗ |
| Published specification | Conveyors, pumps, and fans Source ↗ |
| Published specification | Water treatment and automation systems Source ↗ |
Published ranges and options describe this model or family; confirm the selected configuration for your application.
Datasheets & technical documents
- NVF3M-VFD-Catalog.pdf ↗Catalog
- 2103-NVF3M-VFD-Manual.pdf ↗Manual
Project suitability: Global catalog range. Canadian project suitability, certification and availability must be confirmed for the selected model.
Discuss your requirements
- Application and installation environment
- Electrical ratings and required configuration
- Quantity, project location and delivery requirements
PRODUCT KNOWLEDGE FOR YOUR TEAM
Want to learn about this product?
Discuss NVF3M with Innovelec. Bring your application questions, compare options, or arrange a session for your team.
LET US HELP YOU FIND IT
Can’t find what you need?
Tell us the model, application or specifications. Our team can help identify the right product and request missing technical information.
YOUR PROJECT SHORTLIST
Quote list 0
Add products to prepare one inquiry for our team.
Your inquiry is sent only when you send the email. Include your project location, specifications and required date. You can attach drawings in your email app.