Circuit protection & motor control · Model / SKU
Ex9CS09D10F
Contactor, Ex9CS, Miniature, FVNR, 9A, DC, 1NO, 110V, 3NO
Specifications
| Characteristic | Published value |
|---|---|
| Manufacturer item number | 1320333 |
| Product family | Ex9C Mini Contactor - 6A - 12A |
| Listed configuration | Contactor, Ex9CS, Miniature, FVNR, 9A, DC, 1NO, 110V, 3NO |
| Primary brand | NOARK Source ↗ |
| Main function | Contactor Source ↗ |
| Product series / family name | Industrial controls > Contactors > Standard contactors > DOL / FVNR Source ↗ |
| Sub-range name | Ex9CS series Source ↗ |
| Functions | Miniature contactor Source ↗ |
| Poles | 3-poles (3P; 3NO) Source ↗ |
| Rated current | 9A (380/400Vac; AC-3) 4.9A (660/690Vac; AC-3) 20A (690Vac; AC-1) 15A (24Vdc; DC-1; 1P/2P/3P series connection) 15A (48/75Vdc; DC-1; 1P/2P/3P series connection) 4A (125Vdc; DC-1; 1P series connection) 15A (125Vdc; DC-1; 2P/3P series connection) 1A (225Vdc; DC-1; 1P series connection) 4A (225Vdc; DC-1; 2P series connection) 15A (225Vdc; DC-1; 3P series connection) 15A (24Vdc; DC-2 to DC-5; 1P/2P/3P series connection) 5A (48/75Vdc; DC-2 to DC-5; 1P series connection) 15A (48/75Vdc; DC-2 to DC-5; 2P/3P series connection) 1.5A (125Vdc; DC-2 to DC-5; 1P series connection) 11A (125Vdc; DC-2 to DC-5; 2P series connection) 15A (125Vdc; DC-2 to DC-5; 3P series connection) 0.5A (225Vdc; DC-2 to DC-5; 1P series connection) 1.5A (225Vdc; DC-2 to DC-5; 2P series connection) 5A (225Vdc; DC-2 to DC-5; 3P series connection) 6A (120Vac; AC-15) 3A (240Vac; AC-15) 1.9A (380Vac; AC-15) 1.2A (600Vac; AC-15) 1.1A (125Vdc; DC-13) 0.55A (250Vdc; DC-13) 20A (Ith conventional free air thermal current at 40°C ambient) 20A (Ith conventional free air thermal current at 60°C ambient) 16A (Ith conventional free air thermal current at 70°C ambient) Source ↗ |
| Rated active power (kW) | 4kW (380/400Vac; AC-3) 2kW (230Vac; AC-3) 4kW (660/690Vac; AC-3) Source ↗ |
| Rated power (HP) | 5HP (440-480Vac; 3-phase; UL) 1.5HP / 1-1/2HP (220-240Vac; single-phase; UL) 0.5HP / 1/2HP (110-120Vac; single-phase; UL) 3HP (200-208Vac; 3-phase; UL) 3HP (220-240Vac; 3-phase; UL) 7.5HP / 7-1/2HP (550-600Vac; 3-phase; UL) Source ↗ |
| Rated operating voltage (Ue) | (aux. contacts) 690 V Source ↗ |
| Rated impulse voltage (Uimp) | 6 kV Source ↗ |
| Rated insulation voltage (Ui) | 690 V Source ↗ |
| Connection type | Screw connection M3 screw connection (power circuits) M3 screw connections (auxiliary contact) Source ↗ |
| Cross-section | #18AWG...#12AWG / 1mm2...2.5mm2 conductors (main power connection; bare flexible cable) #18AWG...#12AWG / 1mm2...2.5mm2 conductors (main power connection; bare rigid cable) #18AWG...#12AWG / 1mm2...2.5mm2 conductors (auxiliary contact terminal connection) Source ↗ |
| Control Voltage (DC) | 93.5-121Vdc (110Vdc nom.; 0.85...1.1 x Uc) 11-82.5Vdc drop-out (0.1...0.75 x Uc) -- guaranteed control voltage range where contactor will always open Source ↗ |
| Mounting mode | DIN rail mounting (NS35/7.5) screw mounting on a plate (4mm holes) Source ↗ |
| Normally Open (NO) auxliary contacts | 1 NO contacts Source ↗ |
| Normally Closed (NC) auxiliary contacts | 0 NC contacts Source ↗ |
| Response time | (operating / closing time) 15-40ms / 0.015-0.04 s (drop-off / opening time) 8-15ms / 0.008-0.015 s Source ↗ |
| Contacts type | 1NO (1 Normally Open) aux. contact Source ↗ |
| Degree of protection | IP20 Source ↗ |
| Dimensions | H58mm x W68mm x L45mm H2.28" x W2.68" x L1.77" Source ↗ |
| Ambient air temperature for operation | -4°F...+140°F / -20°C...+60 °C Source ↗ |
| Ambient air temperature for storage | -76°F...+176°F / -60°C...+80 °C Source ↗ |
| Power consumption | (hold) 4 W (pick-up) 4 W Source ↗ |
| Application type | Direct On Line (DOL) FVNR (Full-Voltage Non-Rv.) 6562ft / 2000m max. height above sea level Source ↗ |
| Order code / Manufacturer SKU | Ex9CS09D10F 1320333 Source ↗ |
| Manufacturer product status | Commercialized Source ↗ |
| Equivalent to | 1320333 Source ↗ |
| Compliant with standard(s) | UL 508 (file number E353866) IEC 60947 EN 60947 CSA CCC RoHS compliant Production Standard -- IEC 60947-1 Production Standard -- IEC 60947-4-1 Production Standard -- UL 60947-1 Production Standard -- UL 60947-4-1 Environmental Testing According to IEC 60068-2-1 / IEC 60068-2-2 / IEC 60068-2-11 / IEC 60068-2-30 Source ↗ |
| Electrical durability | (AC-4; 380/400V) 50 000 hours (AC-3; 380/400V) 120 000 hours Source ↗ |
| Mechanical durability | 10 000 000 hours Source ↗ |
| Operating rate | (AC-3) 1200 Cycles/hour (AC-4) 300 Cycles/hour Source ↗ |
| Tightening torque | (main power terminal connection) 0.8 N.m (auxiliary contact connection) 0.8 N.m Source ↗ |
| Degree of pollution | Class III Source ↗ |
| Benefits | Ex9C contactors are intended for various applications including heavy industrial loads. 9 frame sizes allows optimization of electrical parameters and mechanical dimensions. A range of overload relays are available in a variety of frame sizes to fit respective contactors of given rated current. - Nine frame sizes with rated current up to 1000A at 690V AC-3 - Coil control voltage available in AC and DC with ranges from 24-600V - Wide range electronic coil available for 9-500A contactors features built-in surge suppression - DIN rail 35mm and panel mountable Source ↗ |
Published ranges and options describe this model or family; confirm the selected configuration for your application.
Datasheets & technical documents
- E-PLAN - NOARK - Ex9CS09D10F - Part details ↗Technical document
- NOARK - Industrial controls - Catalog.pdf ↗Technical document
- Access to all NOARK drawings ↗Technical document
Exact model page and technical documents linked
Discuss your requirements
- Application and installation environment
- Electrical ratings and required configuration
- Quantity, project location and delivery requirements
PRODUCT KNOWLEDGE FOR YOUR TEAM
Want to learn about this product?
Discuss Ex9CS09D10F with Innovelec. Bring your application questions, compare options, or arrange a session for your team.
LET US HELP YOU FIND IT
Can’t find what you need?
Tell us the model, application or specifications. Our team can help identify the right product and request missing technical information.
YOUR PROJECT SHORTLIST
Quote list 0
Add products to prepare one inquiry for our team.
Your inquiry is sent only when you send the email. Include your project location, specifications and required date. You can attach drawings in your email app.