MANUFACTURERS’ AGENTS TO THE ENERGY INDUSTRYWESTERN CANADA
Innovelec Canada

Circuit protection & motor control · Model / SKU

Ex9CS09DBB

Contactor, Ex9CS, Miniature, FVNR, 9A, DC, 24V, 2NO+2NC

Specifications

Manufacturer-published characteristics
CharacteristicPublished value
Manufacturer item number1320529
Product familyEx9C Mini Contactor - 6A - 12A
Listed configurationContactor, Ex9CS, Miniature, FVNR, 9A, DC, 24V, 2NO+2NC
Primary brandNOARK Source ↗
Main functionContactor Source ↗
Product series / family nameIndustrial controls > Contactors > Standard contactors > DOL / FVNR Source ↗
Sub-range nameEx9CS series Source ↗
FunctionsMiniature contactor Source ↗
Poles4-poles (4P; 2NO+2NC) Source ↗
Rated current20A (690Vac; AC-1) 9A (380/400Vac; AC-3) 4.9A (660/690Vac; AC-3) 15A (24Vdc; DC-1; 1P/2P/3P series connection) 15A (48/75Vdc; DC-1; 1P/2P/3P series connection) 4A (125Vdc; DC-1; 1P series connection) 15A (125Vdc; DC-1; 2P/3P series connection) 1A (225Vdc; DC-1; 1P series connection) 4A (225Vdc; DC-1; 2P series connection) 15A (225Vdc; DC-1; 3P series connection) 15A (24Vdc; DC-2 to DC-5; 1P/2P/3P series connection) 5A (48/75Vdc; DC-2 to DC-5; 1P series connection) 15A (48/75Vdc; DC-2 to DC-5; 2P/3P series connection) 1.5A (125Vdc; DC-2 to DC-5; 1P series connection) 11A (125Vdc; DC-2 to DC-5; 2P series connection) 15A (125Vdc; DC-2 to DC-5; 3P series connection) 0.5A (225Vdc; DC-2 to DC-5; 1P series connection) 1.5A (225Vdc; DC-2 to DC-5; 2P series connection) 5A (225Vdc; DC-2 to DC-5; 3P series connection) 6A (120Vac; AC-15) 3A (240Vac; AC-15) 1.9A (380Vac; AC-15) 1.2A (600Vac; AC-15) 1.1A (125Vdc; DC-13) 0.55A (250Vdc; DC-13) 20A (Ith conventional free air thermal current at 40°C ambient) 20A (Ith conventional free air thermal current at 60°C ambient) 16A (Ith conventional free air thermal current at 70°C ambient) Source ↗
Rated active power (kW)4kW (380/400Vac; AC-3) 2kW (230Vac; AC-3) 4kW (660/690Vac; AC-3) Source ↗
Rated power (HP)5HP (440-480Vac; 3-phase; UL) 1.5HP / 1-1/2HP (220-240Vac; single-phase; UL) 0.5HP / 1/2HP (110-120Vac; single-phase; UL) 3HP (200-208Vac; 3-phase; UL) 3HP (220-240Vac; 3-phase; UL) 7.5HP / 7-1/2HP (550-600Vac; 3-phase; UL) Source ↗
Rated operating voltage (Ue)(aux. contacts) 690 V Source ↗
Rated impulse voltage (Uimp)6 kV Source ↗
Rated insulation voltage (Ui)690 V Source ↗
Connection typeScrew connection M3 screw connection (power circuits) M3 screw connections (auxiliary contact) Source ↗
Cross-section#18AWG...#12AWG / 1mm2...2.5mm2 conductors (main power connection; bare flexible cable) #18AWG...#12AWG / 1mm2...2.5mm2 conductors (main power connection; bare rigid cable) #18AWG...#12AWG / 1mm2...2.5mm2 conductors (auxiliary contact terminal connection) Source ↗
Control Voltage (DC)20.4-26.4Vdc (24Vdc nom.; 0.85...1.1 x Uc) 2.4-18Vdc drop-out (0.1...0.75 x Uc) -- guaranteed control voltage range where contactor will always open Source ↗
Mounting modeDIN rail mounting (NS35/7.5) screw mounting on a plate (4mm holes) Source ↗
Normally Open (NO) auxliary contacts0 NO contacts Source ↗
Normally Closed (NC) auxiliary contacts0 NC contacts Source ↗
Response time(operating / closing time) 15-40ms / 0.015-0.04 s (drop-off / opening time) 8-15ms / 0.008-0.015 s Source ↗
Degree of protectionIP20 Source ↗
DimensionsH58mm x W68mm x L45mm H2.28" x W2.68" x L1.77" Source ↗
Ambient air temperature for operation-4°F...+140°F / -20°C...+60 °C Source ↗
Ambient air temperature for storage-76°F...+176°F / -60°C...+80 °C Source ↗
Power consumption(hold) 4 W (pick-up) 4 W Source ↗
Application typeDirect On Line (DOL) FVNR (Full-Voltage Non-Rv.) 6562ft / 2000m max. height above sea level Source ↗
Order code / Manufacturer SKUEx9CS09DBB 1320529 Source ↗
Manufacturer product statusCommercialized Source ↗
Equivalent to1320529 Source ↗
Compliant with standard(s)UL 508 (file number E353866) IEC 60947 EN 60947 CSA CCC RoHS compliant Production Standard -- IEC 60947-1 Production Standard -- IEC 60947-4-1 Production Standard -- UL 60947-1 Production Standard -- UL 60947-4-1 Environmental Testing According to IEC 60068-2-1 / IEC 60068-2-2 / IEC 60068-2-11 / IEC 60068-2-30 Source ↗
Electrical durability(AC-4; 380/400V) 50 000 hours (AC-3; 380/400V) 120 000 hours Source ↗
Mechanical durability10 000 000 hours Source ↗
Operating rate(AC-3) 1200 Cycles/hour (AC-4) 300 Cycles/hour Source ↗
Tightening torque(main power terminal connection) 0.8 N.m (auxiliary contact connection) 0.8 N.m Source ↗
Degree of pollutionClass III Source ↗
BenefitsEx9C contactors are intended for various applications including heavy industrial loads. 9 frame sizes allows optimization of electrical parameters and mechanical dimensions. A range of overload relays are available in a variety of frame sizes to fit respective contactors of given rated current. - Nine frame sizes with rated current up to 1000A at 690V AC-3 - Coil control voltage available in AC and DC with ranges from 24-600V - Wide range electronic coil available for 9-500A contactors features built-in surge suppression - DIN rail 35mm and panel mountable Source ↗

Published ranges and options describe this model or family; confirm the selected configuration for your application.

Datasheets & technical documents

Exact model page and technical documents linked

Discuss your requirements

  • Application and installation environment
  • Electrical ratings and required configuration
  • Quantity, project location and delivery requirements

PRODUCT KNOWLEDGE FOR YOUR TEAM

Want to learn about this product?

Discuss Ex9CS09DBB with Innovelec. Bring your application questions, compare options, or arrange a session for your team.

Request an online meeting ↗Request an in-person meeting ↗Choose a preferred date and time. Our team will confirm availability.

LET US HELP YOU FIND IT

Can’t find what you need?

Tell us the model, application or specifications. Our team can help identify the right product and request missing technical information.

Ask us about a product ↗

Contact us ↗

YOUR PROJECT SHORTLIST

Quote list 0

Add products to prepare one inquiry for our team.

Your inquiry is sent only when you send the email. Include your project location, specifications and required date. You can attach drawings in your email app.

Contact us ↗

THE NEXT CONNECTION STARTS WITH YOU

Let’s talk about
your next project.

Connect with our team ↗