eLITE Model ELE (5.3kW - 18kW)
Trystar eLITE Model ELE (5.3kW - 18kW) for emergency lighting inverters applications. Published details include Power Capacity: Single-phase sizes: 5.3kW, 7.5kW, 8.5kW, 10kW, 12.5kW, 14.5kW, 16kW, 18kW; Compliance: UL 924 Emergency Lighting Equipment UL 924 Auxiliary Lighting and Power Equipment UL 1778 Uninterruptible Power Supplies NFPA 101 & NFPA 111 compliant. Ask Innovelec about selection, project requirements and availability.
Specifications
| Characteristic | Published value |
|---|---|
| Power Capacity | Single-phase sizes: 5.3kW, 7.5kW, 8.5kW, 10kW, 12.5kW, 14.5kW, 16kW, 18kW Source ↗ |
| Compliance | UL 924 Emergency Lighting Equipment UL 924 Auxiliary Lighting and Power Equipment UL 1778 Uninterruptible Power Supplies NFPA 101 & NFPA 111 compliant Source ↗ |
| Output | Uninterrupted, regulated, continuous sine wave Maximum 3% harmonic distortion, any single harmonic Voltage regulation: typically better than ± 3% Standby output for “Normally Off” fixtures Source ↗ |
| Input | Voltage Range: +10%, -15% without battery usage Frequency: 60 Hz ± 2.5 Hz Input Current Harmonic Distortion: < 10% Power Factor: Self-correcting to > 0.95 Source ↗ |
| Performance | True no-break system with integral constant voltage transformer Provides highly filtered, spike-free power Isolation: Galvanic Efficiency: 90% typical Total System MTBF: 100,000 hours Source ↗ |
| Noise Rejection | Common Mode: 120 dB Transverse Mode: 70 dB Source ↗ |
| Construction | Modular, front-access cabinet design NEMA 1 enclosure Lockable drop-down panel door Electrically isolated output Source ↗ |
| Protection | Overload and short-circuit proof Standard AC and DC input protection Internal make-before-break bypass switch Generator compatible Source ↗ |
| Monitoring & Testing | Automatic self-testing, data logging, and reporting per NFPA 101 – 7.9.3.1.3 Advanced monitoring system Optional NetMinder Ethernet/MODBUS adapter for network monitoring Source ↗ |
| Options | Zone sensing Control device override (wall switch, occupancy sensor, dimmer) CB trip indicator alarm/light Source ↗ |
Published ranges and options describe this model or family; confirm the selected configuration for your application.
Datasheets & technical documents
- Advanced Remote Monitoring ↗Technical document
- Advanced Remote Monitoring BACnet ↗Technical document
- Advanced Remote Monitoring MODBUS ↗Technical document
- Design Flexibility of Inverters ↗Technical document
- Egress Lighting Integrity Test ↗Technical document
- Multiple Voltage Capabilities ↗Technical document
- Remote Input Command ↗Technical document
- UL924 Aux Lighting and Power ↗Technical document
- Zone Sensing ↗Technical document
- Canada Code Compliance Addendum for Egress Lighting Solutions Brochure Addendum ↗Brochure
- Critical Healthcare Environments ↗Technical document
- eLITE Model ELE (5.3kW – 18kW) Owners Manual ↗Manual
- eLite Model ELE Data Sheet ↗Technical document
- Emergency Lighting Inverters Brochure ↗Brochure
- Model ELE Brochure ↗Brochure
- Remote Monitoring and Communications for Inverters Brochure ↗Brochure
- Model ELE General Specification ↗Specification
Discuss your requirements
- Application and installation environment
- Electrical ratings and required configuration
- Quantity, project location and delivery requirements
PRODUCT KNOWLEDGE FOR YOUR TEAM
Want to learn about this product?
Discuss eLITE Model ELE (5.3kW - 18kW) with Innovelec. Bring your application questions, compare options, or arrange a session for your team.
LET US HELP YOU FIND IT
Can’t find what you need?
Tell us the model, application or specifications. Our team can help identify the right product and request missing technical information.
YOUR PROJECT SHORTLIST
Quote list 0
Add products to prepare one inquiry for our team.
Your inquiry is sent only when you send the email. Include your project location, specifications and required date. You can attach drawings in your email app.