Emergency lighting · Model / series
EON Model EL3 (10kW - 55kW) Three Phase
Trystar EON Model EL3 (10kW - 55kW) Three Phase for emergency lighting inverters applications. Published details include Three-Phase Sizes: 10kW, 13kW, 14kW, 15kW, 16kW, 17kW, 20kW, 22kW, 24kW, 26kW, 28kW, 30kW, 32kW, 33kW, 40kW, 45kW, 50kW, 55kW Optional 52kW rating available with 30-minute runtime only (C-UL listed); Input / Output Voltage: 208/120V, 480/277V, or 600/347V Wye. Ask Innovelec about selection, project requirements and availability.
Specifications
| Characteristic | Published value |
|---|---|
| Three-Phase Sizes | 10kW, 13kW, 14kW, 15kW, 16kW, 17kW, 20kW, 22kW, 24kW, 26kW, 28kW, 30kW, 32kW, 33kW, 40kW, 45kW, 50kW, 55kW Optional 52kW rating available with 30-minute runtime only (C-UL listed) Source ↗ |
| Input / Output Voltage | 208/120V, 480/277V, or 600/347V Wye Source ↗ |
| Input Operating Range | +10%, –15% at full load Source ↗ |
| Input Frequency | 60 Hz ± 2.5% (50 Hz models available) Source ↗ |
| Input Power Factor | > 0.98 pF typical at full load Source ↗ |
| Output Regulation | ± 3% from nominal, typical Source ↗ |
| Output Frequency | ± 0.5% while in battery operation mode Source ↗ |
| Output Voltage Distortion | Typically 3% THD with linear load Source ↗ |
| Overload Capability | 110% for 2 minutes 125% for 30 seconds 150% for 10 seconds 400% for 4 cycles (without static bypass) Source ↗ |
| LED Inrush Rating | Peak overload capability of 1700% to accommodate LED fixture inrush (without static bypass) Source ↗ |
| Efficiency | 90% typical Source ↗ |
| Operating Temperature | UL 924 models: 20°C to 35°C (tested to 40°C under full load/low line input) C-UL models: 20°C (10°C optional) to 40°C Source ↗ |
| Battery Performance | Optimum battery life at 25°C for both UL and C-UL models Source ↗ |
| Battery Runtime | UL 924: 90 minutes at full-rated kW Optional runtimes: 15 minutes to 4 hours C-UL: 30 minutes runtime Source ↗ |
Published ranges and options describe this model or family; confirm the selected configuration for your application.
Datasheets & technical documents
- Advanced Remote Monitoring ↗Technical document
- Advanced Remote Monitoring BACnet ↗Technical document
- Advanced Remote Monitoring MODBUS ↗Technical document
- Design Flexibility of Inverters ↗Technical document
- Egress Lighting Integrity Test ↗Technical document
- Local Control Override ↗Technical document
- Multiple Voltage Capabilities ↗Technical document
- Remote Input Command ↗Technical document
- Seismic Testing and Certification ↗Technical document
- UL924 Aux Lighting and Power ↗Technical document
- Zone Sensing ↗Technical document
- Data Center Brochure ↗Brochure
- Emergency Lighting Inverters Brochure ↗Brochure
- EON Model EL3 Brochure ↗Brochure
- EON Model EL3 Egress Lighting Solutions Brochure ↗Brochure
- Remote Monitoring and Communications for Inverters Brochure ↗Brochure
- EON General Specification (10kW – 33kW) ↗Specification
- EON General Specification (40kW – 55kW) ↗Specification
- EON Model EL3 10-33 kW ↗Manual
- EON Model EL3(10kW – 55kW) Three Phase Owners Manual ↗Manual
- EON Model EL3 Data Sheet ↗Technical document
Discuss your requirements
- Application and installation environment
- Electrical ratings and required configuration
- Quantity, project location and delivery requirements
PRODUCT KNOWLEDGE FOR YOUR TEAM
Want to learn about this product?
Discuss EON Model EL3 (10kW - 55kW) Three Phase with Innovelec. Bring your application questions, compare options, or arrange a session for your team.
LET US HELP YOU FIND IT
Can’t find what you need?
Tell us the model, application or specifications. Our team can help identify the right product and request missing technical information.
YOUR PROJECT SHORTLIST
Quote list 0
Add products to prepare one inquiry for our team.
Your inquiry is sent only when you send the email. Include your project location, specifications and required date. You can attach drawings in your email app.