Monitoring & automation · Model / series
SER-3200/SER-2408
Trystar SER-3200/SER-2408 for monitoring and controls applications. Ask Innovelec about selection, project requirements and availability.
Specifications
| Characteristic | Published value |
|---|---|
| Electrical – Digital Inputs | Number of inputs: 32 (SER-3200) or 24 (SER-2408) Voltage, operating: 24 Vdc (-15% to +10%) Must turn on/off voltage: 20 Vdc (on) / 9 Vdc (off) Input impedance: 10K ohms resistive, 1 mA current draw (max.) Source ↗ |
| Relay Outputs (SER-2408) | Number and type of outputs: 8 Form A, solid-state relays (two groups of four) Voltage operating range: 16 to 30 Vdc (24 Vdc nominal) Current capacity: 2.0 A per relay output (8.0 A per group, 16 A total) Source ↗ |
| High-Speed Trigger Output | Relay type: Form A, solid-state relay Maximum current: 100 mA at 24 Vdc nominal Contact closure characteristics: Momentary contact closure, duration of 100 ms Source ↗ |
| Control Power | Voltage, operating: 24 Vdc (±10%) Burden (max.): Steady state: 10 VA (10 watts) Inrush current: 0.8 A for 5–8 ms Source ↗ |
| Time Synchronization – Input | Protocols Supported: • PTP slave (license key) IEEE 1588-2008 (v2), E2E Default Profile, per Annex J • IRIG-B (via optional EZC-IRIG-B connector), 5V DCLS types B004, B007 • DCF77 (via optional EZC-DCF77 connector), 24 Vdc • RS-485 ASCII (ASCII + Quality) or Inter-device SER (legacy) • NTP (SNTP) client with configurable primary/secondary servers and update interval Source ↗ |
| Time Synchronization – Output | Protocols Supported: • PTP (license key) IEEE 1588-2008 (v2), E2E Default Profile, per Annex J • IRIG-B (via optional PLX-5V connector) unmodulated IRIG-B 5V DCLS type B007) • IRIG-B (via optional PLX-24V connector) 24V DCLS type B007, compatible with STR-IDM) • DCF77 or 1per10 (via PLX-24V connector) 24 Vdc 1 pulse per 10 seconds (via PLX-24 Vdc) • RS-485 ASCII (ASCII + Quality) or SER inter-device time (legacy) Source ↗ |
| Clock Accuracy | < 100 µs (with time source PTP, IRIG-B or DCF77) Source ↗ |
| Holdover | After sync for at least 2.5 min., remains within 100 µs for up to 5 min. after loss of sync Source ↗ |
| Communications | Ethernet Interface 10/100BaseTx (unshielded twisted pair) Protocols: Modbus TCP (port 502), 32 simultaneous TCP connections max. Web server: W3C-compliant (TCP ports 80)FTP file server (port 21), max. 5 simultaneous sessions Source ↗ |
| Memory | SDHC flash memory card (user-accessible) 16 GB standard (32 GB option) Source ↗ |
| Mechanical | Mounting: Standard DIN rail (EN 50022, 35 mm x 15 mm) Wire sizes supported: #24 to #12 AWG (#26 to #14 for EZC 3-position connector) Dimensions (W x H x D): 11.25 x 4.75 x 3.13 in. (286 x 121 x 79 mm) In carton: 12.50 x 6.50 x 4.50 in. (318 x 165 x 114 mm) Weight: 3.0 lbs (1.4 kg); in carton: 3.5 lbs (1.6 kg) Source ↗ |
| Environmental | Temperature: -25º to +70º C (Operating) / -40º to +85º C (Storage)Humidity rating: 5% to 95% RH (non-condensing) at 40º C Source ↗ |
| Regulatory Compliance | UL Listing: UL-61010, UL-508, cUL, CSA C22.2Global standards: CE Mark, RCM Mark, EN standards Radiated Emissions: FCC Class A / EN 55022:2010 (CISPR 22:2008) Class A Source ↗ |
| Sustainability | RoHS-compliant, lead-free Source ↗ |
| Country of Origin | USA Source ↗ |
Published ranges and options describe this model or family; confirm the selected configuration for your application.
Datasheets & technical documents
- CNV-100 RS-485 2-Wire/4-Wire Converter Instruction Bulletin ↗Technical document
- PTP Legacy Interface (PLX-5V/24V) Instruction Bulletin ↗Manual
- Sequence of Events Recorder Instruction Bulletin: PTP Field Upgrade Kit ↗Technical document
- Sequence of Events Recorder Instruction Bulletin: Reference Guide ↗Technical document
- Sequence of Events Recorder Instruction Bulletin: User’s Guide ↗Technical document
- SER-2408 – CyTime Hardware Versions ↗Technical document
- SER-2408 – CyTime XML setup ↗Technical document
- SER-3200 – CyTime Hardware Versions ↗Technical document
- SER-3200 – CyTime XML setup ↗Technical document
- EPMS-HD: Power Management in High Definition Data Sheet ↗Technical document
- SER-3200/SER-2408 Event Recorder Data Sheet ↗Datasheet
- Handout: Sequence of Events Recording (SER) ↗Technical document
- Precision In Action: Major Telecommunications Company Leverages Trystar’s Technology For Data Center Resilience ↗Technical document
- Sequence of Events Recorder (SER) Firmware Update Application Instructions ↗Technical document
- SER-3200/SER-2408 CyTime Firmware Release Notes ↗Technical document
- SER-3200/SER-2408 Firmware Update Instructions ↗Technical document
- Tech Note: Measuring Breaker Opening Times with CyTime SER-3200/2408 ↗Technical document
- Tech Note: Mixing RS485 2-Wire/4-Wire Systems with CNV-100 ↗Technical document
- Tech Note: Multiple STRs Can Share a Single GPS Antenna ↗Technical document
- Tech Note: Overview of 1per10 Time Protocol ↗Technical document
- Tech Note: Overview of ASCII/RS-485 Time Protocol ↗Technical document
- Tech Note: Overview of DCF77 Time Protocol ↗Technical document
- Tech Note: Overview of IRIG-B Time Code Standard for Sequence of Events Recorder ↗Technical document
- Tech Note: Replacing ProTime SER with CyTime SER-3200 ↗Technical document
- Tech Note: SER Device Selection Guide ↗Technical document
- Tech Note: SER Export Events to CSV ↗Technical document
- Tech Note: SER Hi-res Time Sync using PTP ↗Technical document
- Tech Note: SER System Design Guide ↗Technical document
Discuss your requirements
- Application and installation environment
- Electrical ratings and required configuration
- Quantity, project location and delivery requirements
PRODUCT KNOWLEDGE FOR YOUR TEAM
Want to learn about this product?
Discuss SER-3200/SER-2408 with Innovelec. Bring your application questions, compare options, or arrange a session for your team.
LET US HELP YOU FIND IT
Can’t find what you need?
Tell us the model, application or specifications. Our team can help identify the right product and request missing technical information.
YOUR PROJECT SHORTLIST
Quote list 0
Add products to prepare one inquiry for our team.
Your inquiry is sent only when you send the email. Include your project location, specifications and required date. You can attach drawings in your email app.