Monitoring & automation · Model / series
SER-32e
Trystar SER-32e for monitoring and controls applications. Ask Innovelec about selection, project requirements and availability.
Specifications
| Characteristic | Published value |
|---|---|
| Electrical – Digital Inputs | • Number of Inputs: 32 standard, up to 48 with optional expansion modules • Operating Voltage: 24 Vdc (-15% to +10%) • Turn-On Voltage: 20 Vdc • Turn-Off Voltage: 9 Vdc • Input Impedance: 10K ohms resistive, 1 mA Source ↗ |
| High-Speed Trigger Output | • Relay Type: Form A relay • Maximum Current: 100 mA @ 24 Vdc nominal • Contact Closure Duration: 100 ms momentary closure Source ↗ |
| Control Power | • Operating Voltage: 24 Vdc (±10%) • Burden (Steady State): 7 VA maximum • Inrush Current: 0.8 A for 5-8 ms • Ride-Through: >10 seconds Source ↗ |
| Time Synchronization – Input | Protocols supported: • PTP IEEE 1588-2019 (v2.1) • IRIG-B (B004, B007, IEEE 1344, C37.118) • DCF77 • NTP (SNTP) • RS-485 (IRIG-B or DCF77) • Legacy SER inter-device synchronization Source ↗ |
| Time Synchronization – Output | Protocols supported: • PTP IEEE 1588-2019 (v2.1) • IRIG-B (5V and 24V) • DCF77 • 1 Pulse per 10 Seconds (1per10) • ASCII RS-485 • Legacy SER inter-device synchronization Source ↗ |
| Clock Accuracy | < 100 µs (with time source = PTP, IRIG-B or DCF77) Source ↗ |
| Holdover | 5 min. (remains within 100 µs after loss of sync for up to 5 min.) Source ↗ |
| Communications | Ethernet interface: 10/100BaseTx Source ↗ |
| Supported Protocols | • Modbus TCP • Secure Modbus TCP • HTTPS • RESTful API • SNMPv2c / SNMPv3 • PTP • NTP Source ↗ |
| Serial Port | RS-485 (2-wire plus shield) Source ↗ |
| Web Server | Secure browser-based interface (HTML5) Source ↗ |
| Simultaneous TCP Connections | 44 managed connections Source ↗ |
| Mechanical | • Mounting: DIN Rail (EN 50022, 35 mm × 15 mm) • Wire Size: #24 to #12 AWG • Dimensions (W × H × D): 11.5 × 5.0 × 2.62 in. (292 × 127 × 66.5 mm) • Shipping Dimensions: 12.5 × 6.5 × 4.5 in. (318 × 165 × 114 mm) • Weight: 2.4 lbs (1.1 kg) • Packaged Weight: 3.5 lbs (1.6 kg) Source ↗ |
| Environmental | • Operating Temperature: -25°C to +70°C • Storage Temperature: -40°C to +85°C • Humidity: 5% to 95% RH, non-condensing • Altitude: Up to 3,000 m (10,000 ft) Source ↗ |
| Regulatory | • UL 61010-1 • UL 61010-2-201 • CE Mark • EN 61326-1 / IEC 61326-1:2012 • CISPR 11 Class A • FCC Part 15B Class A Source ↗ |
| Sustainability | RoHS 3 (EU Directive 2015/863), REACH (EC 1907/2006) Source ↗ |
| Country of Origin | USA Source ↗ |
Published ranges and options describe this model or family; confirm the selected configuration for your application.
Datasheets & technical documents
- CNV-100 RS-485 2-Wire/4-Wire Converter Instruction Bulletin ↗Technical document
- EZC-IRIG-B / EZC-DCF77 Instruction Bulletin ↗Technical document
- Instruction Bulletin for Digital Input Module eXM-DI-08 ↗Technical document
- Instruction Bulletin for Relay Output Module eXM-RO-08 ↗Technical document
- Instruction Bulletin: PTP Legacy Interface (PLXe-5V) for SER-32e ↗Manual
- Owners Manual for SER-32e ↗Manual
- PTP Legacy Interface (PLX-5V/24V) Instruction Bulletin ↗Manual
- SER-32e Guide Specification ↗Specification
- SER-32e Instruction Bulletin ↗Manual
- Data Center Brochure ↗Brochure
- EPMS-HD: Power Management in High Definition Data Sheet ↗Technical document
- SER-32e Event Recorder Data Sheet ↗Technical document
- Monitoring and Controls ↗Technical document
- Precision In Action: Major Telecommunications Company Leverages Trystar’s Technology For Data Center Resilience ↗Technical document
- Restoring Critical Systems Quickly in the Wake of Network Storms Case Study ↗Technical document
- SER-32e – CyTime Download Instructions ↗Technical document
- SER-32e CyTime Release Notes ↗Technical document
- SER-32e Option Module Quick Start Guide ↗Technical document
- SER-32e Quick Start Guide ↗Technical document
- SER-32e Product Handout ↗Technical document
- Tech Note: Measuring Breaker Opening Times with CyTime SER-3200/2408 ↗Technical document
- Tech Note: Mixing RS485 2-Wire/4-Wire Systems with CNV-100 ↗Technical document
- Tech Note: Multiple STRs Can Share a Single GPS Antenna ↗Technical document
- Tech Note: Overview of 1per10 Time Protocol ↗Technical document
- Tech Note: Overview of ASCII/RS-485 Time Protocol ↗Technical document
- Tech Note: Overview of DCF77 Time Protocol ↗Technical document
- Tech Note: Overview of IRIG-B Time Code Standard for Sequence of Events Recorder ↗Technical document
- Tech Note: Replacing ProTime SER with CyTime SER-3200 ↗Technical document
- Tech Note: SER Device Selection Guide ↗Technical document
- Tech Note: SER Export Events to CSV ↗Technical document
- Tech Note: SER Hi-res Time Sync using PTP ↗Technical document
- Tech Note: SER System Design Guide ↗Technical document
Discuss your requirements
- Application and installation environment
- Electrical ratings and required configuration
- Quantity, project location and delivery requirements
PRODUCT KNOWLEDGE FOR YOUR TEAM
Want to learn about this product?
Discuss SER-32e with Innovelec. Bring your application questions, compare options, or arrange a session for your team.
LET US HELP YOU FIND IT
Can’t find what you need?
Tell us the model, application or specifications. Our team can help identify the right product and request missing technical information.
YOUR PROJECT SHORTLIST
Quote list 0
Add products to prepare one inquiry for our team.
Your inquiry is sent only when you send the email. Include your project location, specifications and required date. You can attach drawings in your email app.