Load banks · Product family
Stationary Load Banks
Trystar Stationary Load Banks for load banks applications. Published details include Power Rating: Up to 3000kW; System Voltages: Up to 600 VAC. Ask Innovelec about selection, project requirements and availability.
Specifications
| Characteristic | Published value |
|---|---|
| Power Rating | Up to 3000kW Source ↗ |
| System Voltages | Up to 600 VAC Source ↗ |
| System Frequencies | 50 or 60 Hz Source ↗ |
| Construction | Outdoor weatherproof design with galvanized steel housing, powder-coat finish, and stainless-steel fasteners, Optional 304/316 stainless enclosures and custom paint colors Source ↗ |
| Main Features | Rated for continuous duty with no cool-down period, Industry’s highest capacity in the smallest footprint, Arctic Duty solutions available for operation down to -40°F, Slide-out resistor case assemblies for simplified maintenance, Branch circuit fusing to virtually eliminate catastrophic failure, Intelligent safety circuits, indicators, and operator controls, Multiple options for local or remote operator control Source ↗ |
| Control Power | External 120 VAC, 1-phase, 60 Hz required for control circuit operation, Optional control power transformer available when 120 VAC is not readily accessible Source ↗ |
| Control Options | Standard manual controls with emergency stop and illuminated switches, Advanced digital or software control. Networked operation – multiple load banks controlled from a single panel, Remote operator control options available Source ↗ |
| Digital Power Meter (Optional) | 3-phase digital power metering system measures 16 load parameters, RS485 (Modbus protocol) for remote reading, PC, PLC, or data logger integration Source ↗ |
| Automatic Load Dump | Provides interface to generator controls, ATS, or building management systems, Automatically disconnects all load steps via NC auxiliary contacts during actual power failure Source ↗ |
| Resistor Technology | PowerDyne™ resistors with stainless support rods and ceramic insulators for rugged outdoor performance Source ↗ |
| Cooling System | Direct-driven, high-performance blower motor, Short-circuit protected with current-limiting fuses, Thermally protected by overload relays Source ↗ |
| Safety Features | Emergency Stop (E-Stop), Airflow failure, overtemperature, motor overload, and wrong voltage protection, Load dump indication. Branch circuit fusing and operator fault indicators Source ↗ |
Published ranges and options describe this model or family; confirm the selected configuration for your application.
Datasheets & technical documents
- Automatic Load Level Control Product Handout ↗Technical document
- LS Series Stationary Load Banks Handout ↗Technical document
- Data Center Brochure ↗Brochure
- Instruction Manual Automatic Load Controller ↗Manual
- Instruction Manual Load Shed Regen ↗Manual
- Instruction Manual Series One Load Bank Controller ↗Manual
- LS Series Stationary Outdoor Resistive Load Bank – LS Series Instruction Manual ↗Manual
- M850 Digital Meter Data Logging Instructions ↗Technical document
- Stationary Load Band Load Shed Regen Instruction Manual ↗Manual
- Stationary Outdoor Resistive Load Bank – LB Series Instruction Manual ↗Manual
- Stationary Outdoor Resistive Load Bank – LS Series Instruction Manual ↗Manual
- LS Series 1000-1500kW Gravity Hood ↗Technical document
- LS Series 2000-3000kW ↗Technical document
- LS Series 2000-3000kW Gravity Hood ↗Technical document
- LS Series 250-800kW ↗Technical document
- LS Series 250-800kW Gravity Hood ↗Technical document
- LS Series 50-200kW ↗Technical document
- LS Series 800-1250kW Gravity Hood ↗Technical document
- M850-MP1 Quick Start Guide ↗Technical document
Discuss your requirements
- Application and installation environment
- Electrical ratings and required configuration
- Quantity, project location and delivery requirements
PRODUCT KNOWLEDGE FOR YOUR TEAM
Want to learn about this product?
Discuss Stationary Load Banks with Innovelec. Bring your application questions, compare options, or arrange a session for your team.
LET US HELP YOU FIND IT
Can’t find what you need?
Tell us the model, application or specifications. Our team can help identify the right product and request missing technical information.
YOUR PROJECT SHORTLIST
Quote list 0
Add products to prepare one inquiry for our team.
Your inquiry is sent only when you send the email. Include your project location, specifications and required date. You can attach drawings in your email app.